Unipower & GIC are a Specialist supplier's to the electrical control panel & automation industries 

Unipower Motor Load (kW) Monitors & Transducers and GIC Monitoring Relays 
Below you'll find a list of all products that have been categorised as “Motor Load (kW) Monitors & Transducers” and  
"Monitoring Relays", for more information contact us on 02476 980833. 

APM10, kW to Analogue Transmitter 0(4)-20mA/0(2)-10v No Longer Available 

APM10 Load Transducer, 3x380Vac, 3x415Vac, 3x400Vac, 3x440Vac Supply,  
From Unipower Transmitter for kW, 3 phase symmetrical load* APM10 may be connected to a 3 phase net of up to 3x500Vac * Measures Power from the formula P = √3 x U x I x cosΦ Φ * Internal Current Transformer* Input Current Range 5, 10, 20, 25, 40, 60 Aac* 24V Power Supply* Analogue output 0(4)-20mA or 0(2)-10V* Galvanic insulation between input and output* Test Voltage 3kV 
 

HPL110, Load Monitor, Machine Protection 3×380 – 440Vac, SPCO 

The Unipower HPL110 is a „low-cost“ member of a family of „Intelligent Power- Control Units“. The unit measures true power-consumtption and shows the consumption as a percentage of the selected power-range. The power- consumption (kW) is calculated from the following formula: P = √3 x U x I x Cosϕ 
The primary function of the HPL110 lies in the supervision and control of machinery driven by 3-phased AC-motors. The HPL110 integrates a Max. and/or a Min. kW limit detector plus the support functions necessary to establish the efficient and compact supervision or regulation of various types of machinery such as pumps, ventilators and conveyer belts. The HPL110 has a built in current converter that works up to 8 Amp. 

APM110, Analogue Load Monitor Min/Max 3x380-500V DIN Rail No Longer Available 

Unipower APM110 is a „low-cost“ member of the Unipower family. The unit measures power from the formula: P = √3 x U x I x Cosϕ The primary function of the unit lies in the supervision of machinery driven by 3- phase AC-motors. Unipower APM110 integrates a programmable Max. and Min. kW limit detector plus the support functions necessary to establish the efficient and compact supervision or control of various types of machinery such as pumps, fans and conveyor belts. 

HPL500, Load Monitor, Machine Protection, 3×380 – 440Vac, 110 – 230Vac, 1 X SPCO 1 X SPNO 

Unipower HPL500 is equipped with a specially developed power supply for use from 100V - 575V - both single phased and three phased. Mains voltages in the whole world is hereby covered with one unit. HPL500 also measures currents up to 40A without the use of an external current converter. 
As all Unipower HPL-modules the HPL500 naturally integrates the functions necessary to establish an efficient and compact su- pervision or control; Start timer, reaction timer, setpoints etc. 
For setup simplicity the HPL500 includes peak detectors on the power measurement. 
Additionally also true kW may be displayed as well as the entered kW range. 

APM110E, Load Monitor, Machine Protection, 3×380 – 440Vac, SPCO No Longer Available 

Unipower APM110 is a „low-cost“ member of the Unipower family. The unit measures power from the formula: P = √3 x U x I x Cosϕ 
The primary function of the unit lies in the supervision of machinery driven by 3- phase AC-motors. Unipower APM110 integrates a programmable Max. and Min. kW limit detector plus the support functions necessary to establish the efficient and compact supervision or control of various types of machinery such as pumps, fans and conveyor belts. 
 
 

HPL500MB, Load Monitor, Machine Protection, 3×380 – 440Vac, 110 – 230Vac, 1 X SPCO 1 X SPNO with Modbus 

Unipower HPL500-MB is equipped with a specially developed power supply for use from 100V - 575V - both single phased and three phased. Mains voltages in the whole world is hereby covered with one unit. HPL500-MB also measures currents up to 40A without the use of an external current converter. 
As all Unipower HPL-modules the HPL500-MB integrates the functions necessary to establish an efficient and compact supervision or control; Start ti- mer, reaction timer, setpoints etc. 
For setup simplicity the HPL500 includes peak detectors on the power measurement. 
This MB-version is an RTU-slave on a MODbus network. 
 

PCU D10 front panel Display and Control module for APM110E No Longer Available 

The unit acts as a control/display unit for the Unipower APM110E, to which it is connected with only 2 wires. Although APM110E is a stand alone control module it may be convenient to have a panel mount display. 
Unipower d10 integrates a program- mable Max. and Min. kW limit detector plus the support functions necessary to estab- lish the efficient and compact supervision or control of various types of machinery such as pumps, fans and conveyor belts.  
 
 
 

HPL500H, Remote Terminal Unit 

Unipower HPL500H is a MODbus Remote Terminal Unit made especially for „remote“ control and/or display of Unipower HPL500-MB. 

DON'T KEEP ON GOING ROUND AND ROUND contact us for more information about the Unipower range of load monitors Tel 02476 980833 

GIC Relays and Process Indicators 

MAG03D0424, Phase Failure Relay, 3 PHASE 3/4 WIRE, 120-277VAC, 208-480VAC, 1 C/O 

The MAG03D0424 is a Phase Failure Relay which can be use for both a 3 or 4 wire application, switchable by a dip switch. The Supply voltage can also be selected between 208-480Vac 3 wire and 120-277Vac 4 wire. It has Phase loss, Reversal and Asymmetry as well as adjustable under and over voltage set points. The ON/OFF time delays are also adjustable. All of this in a compact 17.5mm housing. 
 

MJ81BK, 110-240vac PTC Thermistor Relay SPCO DIN Rail 

The MJ81BK is a DIN Rail mounted SPCO Thermistor Over Temperature Monitoring Relay from GIC. It can be powered with the following voltages: 110Vac, 230Vac 

MG53BH, Phase Failure,Rotation and Imbalance relay DPCO 3-Wire 

The MG53BH is a 3 Wire DIN Rail mounted DPCO 3-Phase Voltage (Phase Failure) Monitoring Relay from GIC. It can be powered with the following voltages: 3x400Vac, 3x415Vac 

MJ83BK, 110-240Vac PTC Thermistor Relay, 2 C/O 

The MJ83BK is a DIN Rail mounted DPCO Thermistor Over Temperature Monitoring Relay from GIC. It can be powered with the following voltages: 110Vac, 230Vac 

MG73BH, PhaseFail,Rotation and Imbalance DPCO 240V 1&3P-N (415V) 

The MG73BH is a 4 Wire DIN Rail mounted DPCO 3-Phase Voltage (Phase Failure), Single Phase Voltage Monitoring Relay from GIC. It can be powered with the following voltages: 230Vac, 3x400Vac, 3x415Vac 
 

MJ93BK, 220-440Vac PTC Thermistor Relay,  2 C/O 

The MJ93BK is a DIN Rail mounted DPCO Thermistor Over Temperature Monitoring Relay from GIC. It can be powered with the following voltages: 230Vac, 440Vac 

MG21DH, Phase Failure/Rotation relay.  3 Phase 208-480vac SPCO 

The MG21DH is a 3 Wire DIN Rail mounted SPCO 3-Phase Voltage (Phase Failure) Monitoring Relay from GIC. It can be powered with the following voltages: 3x380Vac, 3x400Vac, 3x415Vac, 3x440Vac 
 
 
 

MJA3BK, 24Vac/dc PTC Thermistor Relay, 2 C/O 

The MJA3BK is a DIN Rail mounted DPCO Thermistor Over Temperature Monitoring Relay from GIC. It can be powered with the following voltages: 24Vac, 24Vdc 

MLD4BS, 400Vac PTC Thermistor & Phase Failure, 2 x NO 

The MLD4BS is a DIN Rail mounted 2 X SPNO Thermistor Over Temperature Monitoring Relay from GIC. It can be powered with the following voltages: 3x400Vac 
 

PIB12C  Process Indicator 

PI, ANALOG I/P+THERMO+RTD I/P, 85-270VAC/DC & 24VDC SENSOR SUPPLY,ALARM RELAY ANALOG  
O/P,RS-485 COMM 

PIB110  Process Indicator 

PI, ANALOG I/P + THERMOCOUPLE + RTD I/P, 85-270VAC/DC & 24VDC SENSOR SUPPLY 

PIB120  Process Indicator 

PI, ANALOG I/P + THERMOCOUPLE + RTD I/P, 85-270VAC/DC & 24VDC SENSOR SUPPLY,ALARM RELAY ANALOG O/P 

PIA200  Process Indicator 

PROCESS INDICATOR, ANALOG INPUT, 180-270VAC 

PIT200  Process Indicator 

PROCESS INDICATOR, THERMOCOUPLE + RTD INPUT, 180-270VAC 
Features 
 
• Flush Mounting Version 96X48 mm with 7 segment display 
• Thermocouple (J, K, T, R & S) / RTD 3-wire (Pt-100) sensor inputs 
• Analog Inputs (0-10 VDC / 0-20mA / 4-20mA), mV (Linear) - 5 to 56mV 
• Alarm Outputs, Analog (0-20mA/ 4-20mA or 0-10V/ 0-5V) & Relay 5A for alarm indication • Configurable Band, Deviation Alarms 
• °C & °F temperature unit selectable 
• Short depth of 65 mm 
• RS 485 Communication 
• IP 20 (For terminal and enclosure) & IP 55 (For Front Panel only) 

DON'T KEEP ON GOING ROUND AND ROUND contact us for more information about the GIC product range Tel 02476 980833 

For more information on the Unipower Load Monitors and the GIC Relays and Process Indicators, please click the buttons below. 

DON'T KEEP ON GOING ROUND AND ROUND contact us for more information about the GIC product range Tel 02476 980833 

Our site uses cookies. For more information, see our cookie policy. Accept cookies and close